Amacan P 500/600

Amacan P


Main applications

  • Advanced treatment / 3.stage
  • Bio. treatment / 2.stage
  • Cooling water and condensate
  • Drainage pump stations
  • Energy
  • Flood / stormwater holding tanks
  • Flood control
  • Heat transfer, Cooling circuits
  • Industrial waste water
  • Industry engineering
  • Irrigation
  • Lake, Damwater extraction
  • Mech. treatment / 1.stage
  • Mining
  • Municipal waste water
  • Power Stations < 100 MW
  • Power Stations > 100 MW
  • Process
  • Sea -& Riverwater Extraction
  • Sewage treatment plants
  • Special processes
  • Surface drainage
  • Suspended solids treatment
  • Waste water
  • Waste water transport
  • Water
  • Water Extraction
  • Watertransport
  • Well

Design type

Submersible pump in discharge tube

Technical data

Q max 25200.0 m³/h
H max 12.0 m

Design

Wet-installed submersible motor pump for installation in discharge tubes, with axial propeller in ECB design, single-stage, single-entry. ATEX-compliant version available.

Application

Irrigation and drainage pumping stations, for stormwater transport in stormwater pumping stations, raw and clean water transport in water and waste water treatment plants, cooling water transport in power stations and industrial plants, industrial water supply, water pollution and flood control, aquaculture.

Further technical information about Amacan P

Overview of technical data

Q (50Hz) 360.0 – 25200.0 (m³/h)
H (50Hz) 0.8 – 12.0 (m)
Type of bearing Rolling element bearings
Casing partition Radially split
Drive Electric motor
Drive frequency 50 Hz /60 Hz
Type of drive Electric motor
Drive voltage Low voltage
Connection to power supply 380 V, 400 V, 690 V, 3~
Explosion protection ATEX II 2G T3
No. of impeller entries Single entry
Impeller material (EN standard) 1.4517
Type of installation Close-coupled
Type of coupling None
Type of lubrication Grease lubrication
Max. permissible fluid temperature 40.0 (°C)
Nozzle position In-line
Pump set location 00
Shaft material (EN standard) 1.4057.05, 1.4021.05
Suction characteristics Non-priming
Type of casing Tubular casing
Type of impeller Axial, Open, Propeller
Casing material (EN standard) JL 1030
eClass assignment 36410101, 36410106
Free passage 255.0 (mm)
Installation position Vertical
Shaft seal type Mechanical seal
Main applications Energy, Mining / Dredges, Water, Waste water / sewage
Casing material Cast iron
Maximum drive rating 700.0 (kW)
Type of installation Stationary
Maximum speed of rotation 1750.0 (1/min)