Evamatic-Box N
Main applications
- Building services
- Drainage
- Pressure Drainage
- Sewage lifting units
- Waste water
- Waste water / sewage
- Waste water lifting units
Technical data
Q max
40.0 m³/h
H max
21.0 m
Design
Floodable lifting unit for domestic waste water, equipped with either one or two pumps of type Ama-Porter F (free-flow impeller) or Ama-Porter S (cutter)
Application
Disposal of domestic and municipal waste water occurring below the flood level
Further technical information about Evamatic-Box N
Overview of technical data
Q (50Hz) | 0.0 – 40.0 (m³/h) |
H (50Hz) | 1.0 – 21.0 (m) |
Type of bearing | Ball bearings |
Cutter | Yes |
Drive frequency | 50 Hz |
Type of drive | Electric motor |
Drive voltage | Low voltage |
Type of coupling | None |
Type of lubrication | Grease lubrication |
Max. permissible fluid temperature | 40.0 (°C) |
Number of pumps | 2 |
Pump set location | Dry installed, floodable |
Shaft material (EN standard) | 1.4021 |
Type of casing | Volute casing |
Type of impeller | Cutter, Free flow impeller |
Type of connection | Screw-ended, flange |
UNSPSC classification | 4015150300 |
Casing material (EN standard) | PE |
eClass assignment | 36410101 |
Free passage | 60 |
Installation position | Vertical |
Shaft seal type | Mechanical seal, Shaft seal ring |
Main applications | Waste water / sewage, Building services |
Casing material | Cast iron |
Maximum drive rating | 1.5 (kW) |
Type of installation | Stationary |
Maximum speed of rotation | 2900.0 (1/min) |