RHM

RHM


Main applications

  • Energy
  • Nuclear Island
  • Nuclear Power Stations

Technical data

Q max 300.0 m³/h
H max 2,100.0 m

Design

Horizontal multistage barrel pull-out pump.

Application

Core flooding, emergency cooling and residual heat removal systems, chemical and volume control systems, control rod drive systems, high-pressure and medium-pressure safety injection systems, emergency feed water systems, start-up and shut-down feed water systems, high-pressure charging.

Further technical information about RHM

Overview of technical data

Q (50Hz) 0.0 – 300.0 (m³/h)
H (50Hz) 0.0 – 2,100.0 (m)
Drive frequency 50 Hz /60 Hz
Type of coupling Direct, Gear
Max. permissible fluid temperature 180.0 (°C)
Standard ASME SECT. III, KTA, RCC-M
Installation position Horizontal
Shaft seal type Mechanical seal
Main applications Energy
Maximum discharge-side pressure 220.0 (bar)
Maximum speed of rotation 8000.0 (1/min)