ES000152-ETA-VL-OEL

ETA VL Öl


Main applications

  • Energy
  • Power Stations < 100 MW
  • Power Stations > 100 MW
  • Turbine oil supply

Design type

Long-coupled design

Technical data

Q max 1,600.0 m³/h
H max 150.0 m

Design

Vertical, radially split volute casing pump.

Applications

For turbine oil transport in fossil-fired and nuclear power stations.

Further technical information about ETA VL Öl

Overview of technical data

Q (50Hz) 1.0 – 1,600.0 (m³/h)
H (50Hz) 9.0 – 150.0 (m)
Type of bearing Ball and plain bearings
Casing partition Radially split
Drive frequency 50 Hz /60 Hz
Type of drive Electric motor
Drive voltage Low voltage
No. of impeller entries Single entry
Type of coupling Direct
Type of lubrication Grease / Product lubrication
Max. permissible fluid temperature 160.0 (°C)
Nozzle position Side-top
Maximum operating pressure PN 10, PN 16
Pull-out design Yes
Pump set location Wet well
Suction characteristics Non-priming
Type of casing Volute casing
Type of impeller Multi-vane impeller, Closed, Radial, Closed / Radial
Type of connection Flange
eClass assignment 36410101, 36410000, 36410100
Installation position Vertical
Shaft seal type Mechanical seal
Main applications Energy
Casing material Cast iron
Maximum discharge-side pressure 16.0 (bar)
Maximum drive rating 22.0 (kW)
Type of installation Stationary
Maximum speed of rotation 3500.0 (1/min)