Neuer Inhalt (1)

Magnochem-Bloc


Main applications

  • Biofuels
  • Cooling water and condensate
  • Energy
  • Industry engineering
  • Oil /Gas
  • Petrochemical Industry
  • Power Stations > 100 MW

Design type

Close-coupled design

Technical data

Q max 754.0 m³/h
H max 236.0 m

Design

Horizontal, seal-less, close-coupled, mag-drive volute casing pump to ISO 2858 / ISO 5199, single-stage, single-entry, with radial impeller. Design to ATEX.

Applications

Handling of aggressive, toxic, explosive, valuable, flammable, malodorous or harmful liquids in the chemical, petrochemical and general industry.

Further technical information about Magnochem-Bloc

Overview of technical data

Q (50Hz) 1.0 – 754.0 (m³/h)
H (50Hz) 3.5 – 236.0 (m)
Type of bearing Plain bearings
Casing partition Radially split
Drive frequency 50 Hz /60 Hz
Type of drive Electric motor
Drive voltage Low voltage
No. of impeller entries Single entry
Heatable Yes
Impeller material (EN standard) 1.4408, JL 1040, NORIDUR 1.4593
Type of installation Close-coupled
Type of coupling Direct
Type of lubrication Product lubrication
Max. permissible fluid temperature 200.0 (°C)
Nozzle position End suction
Maximum operating pressure PN 40
Pull-out design Yes
Pump set location Dry installed
Shaft material (EN standard) 1.4313+QT780, 1.4462
Suction characteristics Non-priming
Type of casing Volute casing
Type of impeller Multi-vane impeller, Closed, Closed / Radial, Radial
Type of connection Flange
Casing material (EN standard) 1.4408, 1.7709, GP240GH+N, NORIDUR 1.4593
eClass assignment 36410101, 36410100, 36410000
Installation position Horizontal or vertical
Shaft seal type Magnetic drive
Main applications Industry and process engineering, Energy
Casing material Cast steel, Cast stainless steel
Maximum discharge-side pressure 40.0 (bar)
Maximum drive rating 90.0 (kW)
Type of installation Stationary
Maximum speed of rotation 3500.0 (1/min)