ES000003-UPA

UPA


Main applications

  • Energy
  • Groundwaterlevel (mining/buildings)
  • Industry engineering
  • Irrigation
  • Lake, Damwater extraction
  • Mining
  • Power Stations < 100 MW
  • Process
  • Water
  • Water Extraction
  • Water treatment
  • Watertransport
  • Well

Design type

Wet well pumps

Technical data

Q max 1010.0 m³/h
H max 480.0 m

Design

Single- or multistage centrifugal pumps in ring-section design, single entry; for vertical and depending on the number of stages horizontal installation; radial or mixed flow hydraulic systems available with reduced impeller diameters; driven by submersible motors.

Applications

Pumping clean or slightly contaminated water in general water supply, irrigation and spray irrigation systems, lowering and maintaining ground water levels, pressure boosting, emergency water supply, mines and fountains etc. Suction casing fitted between pump and motor, equipped with strainer to protect the pump from coarse particles in the fluid. Permissible sand content in the fluid: 50 g/m³. Pumps with non-return valve or connection branch on option.

Type series

S 100D, UPA 100C, UPA 150C, UPA 200, UPA 200B, UPA 250C, UPA 300, UPA 350, UPZ, BSX - BSF.

Further technical information about UPA

Overview of technical data

Q (50Hz) 22.0 – 1010.0 (m³/h)
H (50Hz) 15.0 – 480.0 (m)
Type of bearing Plain bearings
Borehole diameter (inc 14, 08, 10, 12, 06
Casing partition Radially split
Diffuser material (EN standard) GJS-400, CUAL10FE5NI5, PPO GF30, CUSN10, GJL-200
Drive Electric motor
Drive frequency 50 Hz /60 Hz
Type of drive Electric motor
Drive voltage Low voltage, high voltage
Connection to power supply < 6,6 kV, 3~
Type of first impeller Radial / Mixed flow
No. of impeller entries Single entry
Other impeller types Radial / Mixed flow
Impeller material (EN standard) CUSN10, CC480K, PPO GF30
Type of coupling Direct
Type of lubrication Product lubrication
Discharge casing material (EN standard) JL 1040, JL 1030, CC480K, JS 1030
Max. permissible fluid temperature 50.0 (°C)
Maximum operating pressure PN64
Pump set location Wet well
Shaft material (EN standard) 1.4462, 1.4021
Stage casing material (EN standard) JS 1030, JL1030, CC333G, JL 1040, CC480K, GJL-200, CUSN10, CUAL10FE5NI5, GJS-400
Suction casing material (EN standard) GJS-400, GJL-200, CUAL10FE5NI5, CUSN10, JS 1030, JL1030, CC480K
Suction characteristics Non-priming
Suitable for drinking water Yes
Type of connection Screw-ended, flange
Type of stage casing Stage casing with diffuser
Type of suction casing Annular casing
UNSPSC classification 4015150300
Casing material (EN standard) GJL-200, JS1030, JL 1030, 1.4593, CUAL10FE5NI5, CC480K, 1.4408, CUSN 10, GJS-400, CC333G, JL1030
eClass assignment 36410000, 00000000, 36410106, 36410100
Installation position Horizontal or vertical
Shaft seal type Mechanical seal, Shaft seal ring
Casing material Nodular cast iron, Bronze
Maximum discharge-side pressure 57.0 (bar)
Maximum drive rating 380.0 (kW)
Type of installation Stationary
Maximum speed of rotation 3500.0 (1/min)