ES000516-Etanorm-RSY

Etanorm-RSY


Main applications

  • Biofuels
  • Breweries
  • Building services
  • Chemical industry
  • Food and beverages
  • Heating / ventilation / air-condition
  • Industry engineering
  • Irrigation
  • Municipal waste water
  • Pressure boosting
  • Rawwater transport
  • Steel
  • Systems
  • Waste water
  • Water
  • Water supply
  • Watertreatment

Design type

Long-coupled design

Technical data

Q max 2280.0 m³/h
H max 90.0 m

Design

Horizontal, long-coupled volute casing pump in back pull-out design with ratings and main dimensions to EN 733, single-stage, with replaceable casing wear rings. Design to ATEX.

Applications

Heat transfer systems (DIN 4754, VDI 3033) or hot water recirculation (DIN 4752).

Further technical information about Etanorm-RSY

Overview of technical data

Q (50Hz) 50.0 – 2280.0 (m³/h)
H (50Hz) 12.0 – 90.0 (m)
Type of bearing Rolling element and plain bearings
Casing partition Radially split
Drive frequency 50 Hz /60 Hz
Type of drive Electric motor
Drive voltage Low voltage
No. of impeller entries Single entry
Impeller material (EN standard) JL1040, GJL-250, 1.4408
Type of installation Long-coupled
Type of coupling Direct
Type of lubrication Grease / Product lubrication
Max. permissible fluid temperature 350.0 (°C)
Nozzle position End suction
Maximum operating pressure PN 16
Pull-out design Yes
Pump set location Dry installed
Shaft material (EN standard) 1.4057.05
Suction characteristics Non-priming
Type of casing Volute casing
Type of impeller Radial
Type of connection Flange
Casing material (EN standard) GJS-400-18-LT, JS1025
eClass assignment 36410100, 36410000, 36410101
Installation position Horizontal
Shaft seal type Mechanical seal
Main applications Industry and process engineering
Casing material Nodular cast iron
Maximum discharge-side pressure 16.0 (bar)
Type of installation Stationary
Maximum speed of rotation 1750.0 (min)